HEL2 Site Information Form (site log) International GNSS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : GREF Operator Date Prepared : 2019-02-12 Report Type : NEW If Update: Previous Site Log : Modified/Added Sections : 1. Site Identification of the GNSS Monument Site Name : Leipzig / Germany Four Character ID : LEI3 Monument Inscription : IERS DOMES Number : 14267M003 CDP Number : (A4) Monument Description : STEEL PILLAR Height of the Monument : x.xx m Monument Foundation : PILLAR ANCHORED TO THE ROOF Foundation Depth : (m) Marker Description : STEEL SURVEY MARKER BOLT Date Installed : Geologic Characteristic : (BEDROCK/CLAY/CONGLOMERATE/GRAVEL/SAND/etc) Bedrock Type : (IGNEOUS/METAMORPHIC/SEDIMENTARY) Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (0 cm/1-10 cm/11-50 cm/51-200 cm/over 200 cm) Fault zones nearby : (YES/NO/Name of the zone) Distance/activity : (multiple lines) Additional Information : The Steel Pillar is anchored : to the roof on the building of : the BKG in Leipzig. The antenna : is about 32 m above the ground. 2. Site Location Information City or Town : Leipzig State or Province : Sachsen Country : Germany Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 3898752.275 Y coordinate (m) : 855322.799 Z coordinate (m) : 4958363.710 Latitude (N is +) : +512113.88 Longitude (E is +) : +0122225.44 Elevation (m,ellips.) : 178.25 Additional Information : (multiple lines) 3. GNSS Receiver Information 3.1 Receiver Type : JAVAD TRE_3 DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 02883 Firmware Version : 3.7.5p1 JAN,23,2019 Elevation Cutoff Setting : 0 deg Date Installed : 2019-02-13T13:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : none Additional Information : Board Id : 193NV209A3QCX0QDSPVJA2QGHS 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TPSCR.G3 TPSH Serial Number : 383-0208 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0450 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : TPSH Radome Serial Number : Antenna Cable Type : Ecoflex 15 Antenna Cable Length : 70 m Date Installed : 2019-02-13T13:00Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : P/N 01-044301-01 : Antenna calibrated absolute : by GEO++ GmbH Garbsen 2007-11-13 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : (if external) Effective Dates : 2019-02-13/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : WXTPTU Manufacturer : Vaisala Serial Number : J2420008 Data Sampling Interval : 10 sec Accuracy (% rel h) : 3 Aspiration : NATURAL Height Diff to Ant : (m) Calibration date : 2013-06-14 Effective Dates : 2019-02-12/CCYY-MM-DD Notes : Vaisala WXT520 (heated) SN: J2440013 : Humidity Sensor is x.x m under/above the antenna : capacitive thin film polymer HUMICAP 180 sensor 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : WXTPTU Manufacturer : Vaisala Serial Number : J2420008 Data Sampling Interval : 10 sec Accuracy : 1 hPa Height Diff to Ant : (m) Calibration date : 2013-06-14 Effective Dates : 2019-02-12/CCYY-MM-DD Notes : Vaisala WXT520 (heated) SN: J2440013 : Pressure Sensor is x.x m under/above the antenna : capacitive silicon BAROCAP sensor 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.3 Temp. Sensor Model : WXTPTU Manufacturer : Vaisala Serial Number : J2420008 Data Sampling Interval : 10 sec Accuracy : 0.3 deg C Aspiration : NATURAL Height Diff to Ant : (m) Calibration date : 2013-06-14 Effective Dates : 2019-02-12/CCYY-MM-DD Notes : Vaisala WXT520 (heated) SN: J2440013 : Temperature Sensor is x.x m under/above the antenna : capacitive ceramic THERMOCAP sensor 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.1 Other Instrumentation : Wind Azimut : Wind Sensor Model WXT520 (heated) : Manufacturer Vaisala : Serial Number J2440013 : Data Sampling Interval 10 sec : Accuracy 3 deg : Height Diff to Ant (m) : Test date 2013-06-14 : Effective Dates 2019-02-12/CCYY-MM-DD : Notes Wind Sensor is x.x m under/above the antenna : Notes ultrasonic WINDCAP sensor 8.5.2 Other Instrumentation : Wind Speed : Wind Sensor Model WXT520 (heated) : Manufacturer Vaisala : Serial Number J2440013 : Data Sampling Interval 10 sec : Accuracy : measurement values 0..35 m/s 0.3 m/s or 3% : measurement values 36..60 m/s 5% : Height Diff to Ant (m) : Test date 2013-06-14 : Effective Dates 2019-02-12/CCYY-MM-DD : Notes Wind Sensor is x.x m under/above the antenna : Notes ultrasonic WINDCAP sensor 8.5.3 Other Instrumentation : Rain Increment : Rain Sensor Model WXT520 (heated) : Manufacturer Vaisala : Serial Number J2440013 : Data Sampling Interval 10 sec : Accuracy 5 % : Height Diff to Ant (m) : Test date 2013-06-14 : Effective Dates 2019-02-12/CCYY-MM-DD : Notes Rain Sensor is x.x m under/above the antenna : Notes piezoelectrical RAINCAP sensor 8.5.4 Other Instrumentation : Hail Indicator : Hail Sensor Model WXT520 (heated) : Manufacturer Vaisala : Serial Number J2440013 : Data Sampling Interval 10 sec : Accuracy 5 % : Height Diff to Ant (m) : Test date 2013-06-14 : Effective Dates 2019-02-12/CCYY-MM-DD : Notes Hail Sensor is x.x m under/above the antenna : Notes piezoelectrical RAINCAP sensor 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Bundesamt fuer Kartographie und Geodaesie Preferred Abbreviation : BKG Mailing Address : Richard-Strauss-Allee 11 : D-60598 : Frankfurt a.M. Primary Contact Contact Name : BKG GNSS Data Center Telephone (primary) : +49 69 6333274 Telephone (secondary) : +49 69 63331 Fax : +49 69 6333425 E-mail : bkg-gdc@bkg.bund.de Secondary Contact Contact Name : GREF Operator Telephone (primary) : +49 341 5634333 Telephone (secondary) : Fax : +49 341 5634415 E-mail : dlz@bkg.bund.de Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : (multiple lines) Preferred Abbreviation : (A10) Mailing Address : (multiple lines) Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : BKG Secondary Data Center : OLG URL for More Information : www.bkg.bund.de Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : (Y or URL) Additional Information : (multiple lines) Antenna Graphics with Dimensions TPSCR.G3 +-------+ / + \ | + | +-----------------+-------------+------------------+ <-- 0.1015 TCR | | | | | | | | +-+--------------------------------------------------+-+ +-------------------+-------------+--------------------+ <-- 0.0345 BCR | | | | +------x------+ <-- 0.000 BPA=ARP <-- 0.238 --> <-- 0.380 --> ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering TGP: Top of Ground Plane BGP: Bottom of Ground Plane TPA: Top of Preamplifier BPA: Bottom of Preamplifier TOP: Top of Pole All dimensions are in meters.